Model Number : LUGBML

Place of Origin : China

MOQ : 1pc

Price : Negotiation

Payment Terms : T/T

Supply Ability : 500pcs per month

Delivery Time : 7-10 working days

Packaging Details : In Carton or Wooden Box

Product Name : Vortex Flow Meter

Application : Oil,chemical industry,metallurgy,heating power,spinning,paper making ,etc.

Accuracy : ±1.0% for Liquid, ±1.5% for Gas

Ambient Temperature : -35℃~60℃(without LCD);-5℃~60℃(with LCD)

Working Pressure : 1.6MPa(standard), 2.5~4.0MPa(according to customer's requirements)

IP Class : IP65

Contact Now

Anti Vibration Intelligent Vapour Vortex Flow Meter with Saturated Steam

1. Introduction
LUGBML is based on Von Karman’s Vortex Principle, which adopts piezoelectric crystal as testing components. It is a new kind of stress detecting vortex flow meter. It has the advantage of wide range ratio, high accuracy, low pressure loss, good medium generality, pulse output proportional to flow, convenient to connect with computer and etc. As the detector probe of sensor and the vortex generating body are installed separately, and the high temperature resistant piezoelectric crystal doesn’t contact with medium, so the instrument is of simple structure, good generality and high stability.
LUGBML series Vortex Flow Meter sensor can be used to detect and measure the flow of all kinds of gas, liquid and steam.
LUGBML series Vortex Flow Meter can be used to match with our company’s ML6000 series Velocity Flowmeter. It can also match with a computer and sensors of temperature, pressure, or density to compose high accuracy mass flow or heat flow detecting and measuring system.

2. Features

  • The structure of Vortex Flow Meter is simple and solid, no movable parts and it is very stable.
  • Simple installation and easy maintenance.
  • Wide measuring range, the ratio is up to 10:1.
  • The volume of fluid is compensated according to requirements, and the instrument coefficient does not need to be re-calibrated after the replacement of the accessories.


3. Specifications

1) Measuring medium: Steam,gas, liquid(Avoid of multiple- direction fluid)

2) Accuracy:Liquid:1.0% Gas:1.5%

3) Repeatability:Liquid 0.33% Gas:0.5%

4) Range:Liquid:0.7m/s~7m/s Gas:7m/s~40m/s

5) Working pressure:Standard 1.6MPa,2.5~4.0 MPa (on request)

6) Fluid temperature:-40℃~250℃(Common type);100℃~350℃(High-temperature type)

7) Body material:304 stainless steel(SS316 is optional)

8) Output signal:Pulse(three wires,low level≤1V;High level≧4V);4~20mA;RS485

9) Power supply:24VDC(12VDC),Lithium battery

10) Ambient temperature : -35 ℃ ~ 60 ℃ ( without LCD ); -5℃~60℃(with LCD)

11) Relative humidity:5~95%

12) Protection level:IP65

13) Electrical connection:M20*1.5



4. Configuration

LUGBML Series Vortex Flow Meter Configuration
Model LUGBML
Sensor Installation D Clamp Type Sensor
F Flange Type Sensor
C Insertion Type Sensor
Medium L Liquid
G Gas
S Steam
Pipe Material 25 25mm
......
300 300mm
Power Supply A Duplicate Supply(24VDC/12VDC+3.6V Lithium Battery)
B 3.6V Lithium Battery
C 24VDC/12VDC
Display D With Digital Display
P Without Digital Display
Output N None
P Pulse
A 4-20mA
R RS485
H Hart
Flange Type G GB (Standard)
A ANSI
J JIS
B BS
O Others
Sensor Material A 304 SS (Standard)
B 316 SS
O Others
Medium Temperature E 40~250℃
H 100~350℃
Rated Pressure 16 1.6MPa
25 2.5MPa
40 4.0MPa
O Others
Protection Class 0 IP65
Explosion Proof 0 None
EX Explosive Proof


5. Design & Installation
It is important to install meter,if not installed well, then would affect precision, use-life and damage.
1. To avoid strong current, high frequency and powerful switch set, power supply of meter shall be avoided to near by these equipments.
2. To avoid high-Temp & radiation source. if have to install it, need heat insulation & ventilated measure.
3. To avoid high-Temp & enchant gas, if have to install it, need ventilated measure.
4. Vortex flow meter shall be avoided to install on shaking part of pipeline. If have to install on it,shall add clamp device and vibration pad which located on 2D to enhance shake proof . meter has better to installed indoors, pay attention to waterproof when installing meter outdoors,special notice the joint, make cable conductor to U shape to avoid water get into the amplifier body Around installing place shall save enough space,so that install connection line and maintenance routine.


Product Tags:

vortex gas flow meter

      

vortex steam flow meter

      
China Intelligent Vapour Vortex Air Flow Meter Anti Vibration With Saturated Steam wholesale

Intelligent Vapour Vortex Air Flow Meter Anti Vibration With Saturated Steam Images

Inquiry Cart 0
Send your message to this supplier
 
*From:
*To: Melan Measurement & Control Instruments (Shanghai) Co.,Ltd.
*Subject:
*Message:
Characters Remaining: (0/3000)